ПЛАСТИКА ФИБРОЗНОГО КОЛЬЦА ПОСЛЕ МИКРОДИСКЭКТОМИИ НА ПОЯСНИЧНОМ УРОВНЕ
https://doi.org/10.14531/ss2014.4.116-119
Аннотация
Об авторах
Александр Владимирович КрутькоРоссия
Евгений Сергеевич Байков
Россия
Список литературы
1. Крутько А.В., Байков Е.С. Роль радиологических параметров позвоночно-двигательного сегмента в исходе хирургического лечения грыж поясничных межпозвонковых дисков // Хирургия позвоночника. 2013. № 1. С. 55-63. [Krutko AV, Baikov ES. The role of radiological parameters of spinal motion segment in the outcome of surgical treatment for lumbar intervertebral disc hernia. Hir pozvonoc. 2013;(1):55-63. In Russian]. doi: http://dx.doi.org/10.14531/ss2013.1.55-63.
2. Bouma GJ, Barth M, Ledic D, et al. The high-risk discectomy patient: prevention of reherniation in patients with large anular defects using an anular closure device. Eur Spine J. 2013;22:1030-1036. doi: 10.1007/s00586-013-2656-1.
3. Carragee EJ, Han MY, Suen PW, et al. Clinical outcomes after lumbar discectomy for sciatica: the effects of fragment type and anular competence. J Bone Joint Surg Am. 2003;85:102-108.
4. McGirt MJ, Eustacchio S, Varga P, et al. A prospective cohort study of close interval computed tomography and magnetic resonance imaging after primary lumbar discectomy: factors associated with recurrent disc herniation and disc height loss. Spine. 2009;34:2044-2051. doi: 10.1097/BRS.0b013e3181b34a9a.
5. Mobbs RJ, Newcombe RL, Chandran KN. Lumbar discectomy and the diabetic patient: incidence and outcome. J Clin Neurosci 2001;8:10-13.
6. Parker SL, Grahovac G, Vukas D, et al. Effect of an annular closure device (Barricaid) on same level recurrent disc herniation and disc height loss after primary lumbar discectomy: two-year results of a multi-center prospective cohort study. J Spinal Disord Tech. 2013 Nov 5. [Epub ahead of print].
7. Swartz KR, Trost GR. Recurrent lumbar disc herniation. Neurosurg Focus. 2003;15:E10.
8. Trummer M, Eustacchio S, Barth M, et al. Protecting facet joints post-lumbar discectomy: Barricaid annular closure device reduces risk of facet degeneration. Clin Neurol Neurosurg. 2013;115:1440-1445. doi: 10.1016/j.clineuro.2013.01.007.
9. Yorimitsu E, Chiba K, Toyama Y, et al. Long-term outcomes of standard discectomy for lumbar disc herniation: a follow-up study of more than 10 years. Spine. 2001;26:652-657.
Рецензия
Для цитирования:
Крутько А.В., Байков Е.С. ПЛАСТИКА ФИБРОЗНОГО КОЛЬЦА ПОСЛЕ МИКРОДИСКЭКТОМИИ НА ПОЯСНИЧНОМ УРОВНЕ. Хирургия позвоночника. 2014;(4):116-119. https://doi.org/10.14531/ss2014.4.116-119
For citation:
Krutko A.V., Baikov E.S. THE ANNULUS FIBROSUS PLASTY AFTER LUMBAR MICRODISCECTOMY: A CASE REPORT. Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika). 2014;(4):116-119. (In Russ.) https://doi.org/10.14531/ss2014.4.116-119